Electric Boilers For Sale 300
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Orifice plate flow meters are differential pressure sensors for flow rate. Can be used with gases, liquids, corrosive, and high temperature fluids. Applications include steam flow, boiler feedwater, and fluid flow rates in building water lines. Designed for use wherever there is an application for a conventional flow orifice plate.Get Price
*Optional integral LCD display with BACnet MS/TP or MODBUS RTU is available. LCD display can be mounted up to 5 feet away from flow body for visibility. Typical Applications. The F-4600 inline flow meter is ideal for chilled water, hot water, domestic water, condenser water, steam condensate and boiler feed water.Get Price
Jan 09, 2022 · 800-968-8604 Toll Free 406-300-1776 Local 888-317-0987 Fax Email: [email protected] Hours 8 am - 5 pm (Mountain time). Monday thru FridayGet Price
Dec 24, 2021 · Gas boilers, thanks to condensers, are more efficient than ever but they still burn fuel to heat water. That means at their best you get an efficiency of 94%. Or in other words, for every pound spent six pence is wasted. Heat pumps are a staggering 300-400% efficient.Get Price
Dec 24, 2021 · Gas boilers, thanks to condensers, are more efficient than ever but they still burn fuel to heat water. That means at their best you get an efficiency of 94%. Or in other words, for every pound spent six pence is wasted. Heat pumps are a staggering 300-400% efficient.Get Price
The AlsonicDSP ultrasonic flow meter, not only measures the volumetric flow rate, but also the sonic velocity of the liquid, a PLC or DSC can be programed to relate acid concentration levels versus fluid sonic velocity. There is a direct relationship between sonic velocity and changes of concentration. Boiler feed water system.Get Price
2-path meter for flow measurement of thermal oil, boiler feed water, crudes and hot feed flows in refineries; Up to +600°C / +1112°F; Flange: max. DN1000 / 40" 3 x 4…20 mA, HART ® 7, Modbus, FF, Profibus-PA/DPGet Price
For example, chelant feed can be adjusted automatically, based on analyzer or operator hardness test results, boiler feedwater flow, and minimum/maximum allowable product feed rates. Thus, chemical feed precisely matches system demand, virtually eliminating the …Get Price
Dec 13, 2010 · Heating Water with Steam Example: How many lbs per hour of steam is need to heat 40 gallons per minute flow rate of water from 60 ° F to 180 ° F? Sizing a Boiler Feed Pump Receiver. The receiver tank should be able to hold five minutes worth of condensate for boilers up to 200 BHP and 10 minutes of condensate for boilers over 200 BHP.Get Price